How big a septic tank a house needs, by bedrooms and state

Minimum septic tank sizes in gallons by number of bedrooms under six states' rules, and what a garbage disposal or whirlpool bath adds.

Updated November 25, 2026 · 6 official sources
On this page: 6 sections
  1. 1What is the minimum septic tank size for each number of bedrooms?
  2. 2Does a garbage disposal make the septic tank bigger?
  3. 3How big a septic tank does a house with more than six bedrooms need?
  4. 4Do a whirlpool bath, a sewage pump or compartments change the required size?
  5. 5How is the required tank size worked out from the house's flow?
  6. 6Can you get too big of a septic tank?

Under Minnesota's rule, a house with three or fewer bedrooms needs a septic tank of at least 1,000 gallons, and a house with four or five bedrooms needs 1,500 gallons.1 In New York, septic tank capacities are based on the number of household bedrooms.2

What is the minimum septic tank size for each number of bedrooms?

The capacity of a septic tank is the volume of wastewater, including scum and sludge, held in the tank below the bottom of the outlet.3 In New York, an expansion attic counts as an additional bedroom when a septic tank is sized.2 In Minnesota, the liquid capacity of a dwelling's septic tank must be at least as large as the capacity the rule's Table V gives for the dwelling's bedrooms.1

Other states have their own rules.

State 1 or 2 bedrooms 3 bedrooms 4 bedrooms 5 bedrooms 6 bedrooms Rule
Minnesota 1,000 gallons 1,000 gallons 1,500 gallons 1,500 gallons 2,000 gallons Table V of part 7080.19301
Ohio 1,000 gallons 1,500 gallons 2,000 gallons 2,000 gallons 2,500 gallons plus 250 gallons for each bedroom Rule 3701-29-12(C)(1)4
Georgia 1,000 gallons 1,000 gallons 1,000 gallons 1,000 gallons and 250 additional gallons for each bedroom over four 1,000 gallons and 250 additional gallons for each bedroom over four The capacity paragraph of the septic tank rule5
New York 1,000 gallons 1,000 gallons 1,250 gallons 1,500 gallons 1,750 gallons Table 3 of section 75-A.62
Nebraska 1,000 gallons 1,000 gallons 1,250 gallons 1,500 gallons 1,750 gallons Table II, septic tank sizing for a single dwelling3

In Nebraska, a four-bedroom home requires at least a 1,250-gallon tank.3 The Kansas bulletin's publisher marks the file as kept for historical purposes only and says the file may not reflect current practices.6

Does a garbage disposal make the septic tank bigger?

Where a garbage disposal unit is anticipated or installed in a Minnesota dwelling, the septic tank capacity must be at least 50 percent greater than the bedroom table requires, the tank must have multiple compartments or be multiple tanks, and an effluent screening device is recommended.1 Georgia also increases septic tank capacity by 50 percent if a garbage grinder is to be used.5

New York treats a garbage grinder as equivalent to an additional bedroom when sizing the tank: an additional 250 gallons of capacity and seven square feet of surface area is required when a garbage grinder can reasonably be expected at the time of construction or in the future. A New York tank sized for a garbage grinder must also have a gas deflection baffle or other acceptable outlet modification, and be a dual compartment tank or two tanks in series.2 Kansas's bulletin recommends tanks sized at three times the daily flow and requires that size when garbage disposals are used.6

How big a septic tank does a house with more than six bedrooms need?

Minnesota's table continues to 2,000 gallons for six or seven bedrooms and 2,500 gallons for eight or nine, and a Minnesota house with more than nine bedrooms needs 2,500 gallons plus 250 gallons for each bedroom over nine.1 Ohio's rule for six or more bedrooms is two thousand five hundred gallons plus an additional two hundred fifty gallons of tank capacity for each bedroom, in two tanks or compartments.4

New York sizes a tank for more than six bedrooms by adding 250 gallons and seven square feet of surface area for each additional bedroom.2 Kansas's bulletin adds 300 gallons to the minimum for each additional bedroom.6 In Nebraska, a house with 10 or more bedrooms is an establishment, which is sized under a separate set of rules.3

Do a whirlpool bath, a sewage pump or compartments change the required size?

Nebraska increases tank capacity by 250 gallons when a whirlpool bath is installed in a home of three bedrooms or more, so a four-bedroom Nebraska home with a whirlpool bath requires a 1,500-gallon tank.3 In Minnesota, a dwelling whose sewage is pumped to the septic tank from a sewage ejector or grinder pump needs a tank at least 50 percent larger than the bedroom table requires, and a dwelling with both a pump and a garbage disposal doesn't have to add the two increases together.1

Ohio allows the septic tank for a one or two bedroom home to be in one or two compartments and requires two tanks or compartments from three bedrooms up.4 New York recommends dual compartments for all tanks and requires them on all tanks with an interior length of ten feet or more.2

How is the required tank size worked out from the house's flow?

Design flow in Kansas's bulletin is estimated by multiplying the number of household bedrooms by 150 gallons per day, and the 150 gallons is based on 75 gallons per person per day for two people in each bedroom. The minimum septic tank capacity in the Kansas bulletin is two times the daily wastewater flow, using 150 gallons per bedroom, or 1,000 gallons, whichever is larger. A septic tank in the Kansas bulletin is sized so that wastewater flow through the tank takes at least 24 hours even with sludge and scum accumulation.6

Georgia sizes auxiliary systems serving single family residences on the maximum daily flow instead of bedrooms.5

Can you get too big of a septic tank?

Georgia sets an upper limit: a conventional or chamber septic tank system in Georgia must have a septic tank design capacity of no less than one thousand gallons and no greater than ten thousand gallons.5 New York caps the depth that counts toward a tank's size at 60 inches, so a deeper tank provides extra sludge storage but gets no credit toward design volume.2

In Kansas's bulletin, larger capacity tanks usually mean less carryover of solids, which prolongs the life of the soil absorption field, and larger tanks require less frequent cleaning. The Kansas bulletin's recommended capacity adds 450 gallons for each additional bedroom, against 300 gallons for the minimum.6

Minnesota Rules part 7080.1930, Ohio Administrative Code 3701-29-12, Georgia's on-site sewage rules, New York's Appendix 75-A, Nebraska Extension and a Kansas State University bulletin, checked November 2026.

Sources (6)

  1. Minnesota Revisor of Statutes: Minnesota Rules part 7080.1930, septic tank capacity, read November 25, 2026 ↑
  2. Cornell Legal Information Institute: New York 10 NYCRR Appendix 75-A, section 75-A.6, septic tanks, read November 25, 2026 ↑
  3. Nebraska Extension: residential onsite wastewater treatment, septic tank capacity, read November 25, 2026 ↑
  4. Ohio Laws: Ohio Administrative Code rule 3701-29-12, tanks, pumps and controls, and building sewers, read November 25, 2026 ↑
  5. Georgia Secretary of State: Rules and Regulations subject 511-3-1, on-site sewage management systems, read November 25, 2026 ↑
  6. Kansas State University Research and Extension: Kansas Department of Health and Environment Bulletin 4-2, septic tank, read November 25, 2026 ↑

Find septic companies in your county

Request a quoteSmart search